Executive Dashboard
ALL UNIT
UNIT 1
UNIT 2
UNIT 3
BOP 1&2
BOP 3
COAL ASH
UPDATE SR 31/08/2026
Unit Condition Distribution
Score Distribution
Normal
53 Alat (100%)
Warning
0 Alat (0%)
Danger
0 Alat (0%)
Critical
0 Alat (0%)
Priority Skoring Peralatan
Filter:
×
#
Equipment Name
Score
Status
1
TURBIN VELOCITY
25.1
Normal
2
MOT BFP A
22.5
Normal
3
UNIT 2 - MAIN OIL TANK
22.5
Normal
4
UNIT 3 - MILL PULVERIZER A
22.5
Normal
5
UNIT 3 - MILL PULVERIZER B
22.5
Normal
6
UNIT 3 - MILL PULVERIZER C
22.5
Normal
7
UNIT 3 - MILL PULVERIZER D
22.5
Normal
8
UNIT 3 - BC 9B
22.5
Normal
9
UAT 3
22.5
Normal
10
TURBIN DISPLACEMENT (RMS)
22.5
Normal
11
UNIT 3 - MAIN OIL TANK
20.8
Normal
12
BOILER FEED PUMP B UNIT 3
15
Normal
13
BOILER FEED PUMP C UNIT 3
15
Normal
14
UNIT 3 - IDF A (INDUCED DRAFT FAN)
11.25
Normal
15
UNIT 3 - IDF B (INDUCED DRAFT FAN)
11.25
Normal
16
UNIT 3 - TERTIARY AIR FAN A
2.7
Normal
17
TURBIN DISPLACEMENT (O-P)
2.1
Normal
18
MAIN CIRCULATING WATER PUMP B
2
Normal
19
UNIT 3 - BC 9A
1.8
Normal
20
UNIT 3 - SERVICE WATER PUMP A
0.9
Normal
21
UNIT 3 - FORCED DRAFT FAN A
0
Normal
22
UNIT 3 - FORCED DRAFT FAN B
0
Normal
23
PRIMARY AIR FAN A
0
Normal
24
PRIMARY AIR FAN B
0
Normal
25
UNIT 3 - SCANNER COOLING AIR FAN A
0
Normal
26
UNIT 3 - SCANNER COOLING AIR FAN B
0
Normal
27
UNIT 3 - MAIN CIRCULATING WATER PUMP A
0
Normal
28
UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP A
0
Normal
29
UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP B
0
Normal
30
UNIT 3 - PRIMING PUMP
0
Normal
31
UNIT 3 - BC 10A
0
Normal
32
UNIT 3 - BC 8A
0
Normal
33
UNIT 3 - BC 8B
0
Normal
34
UNIT 3 - BC 7B
0
Normal
35
UNIT 3 - FUEL FORWARDING PUMP A
0
Normal
36
UNIT 3 - FUEL FORWARDING PUMP B
0
Normal
37
UNIT 3 - BC 10B
0
Normal
38
TRAFO GT UNIT 3
0
Normal
39
TRAFO UAT UNIT 3
0
Normal
40
UNIT 3 - CRUSHER A
0
Normal
41
UNIT 3 - BFP C
0
Normal
42
UNIT 3 - PAF A (PRIMARY AIR FAN)
0
Normal
43
UNIT 3 - PAF B (PRIMARY AIR FAN)
0
Normal
44
UNIT 3 - VACUUM PUMP A
0
Normal
45
UNIT 3 - MAIN CIRCULATING WATER PUMP B
0
Normal
46
UNIT 3 - COAL FEEDER A
0
Normal
47
UNIT 3 - COAL FEEDER B
0
Normal
48
UNIT 3 - COAL FEEDER D
0
Normal
49
UNIT 3 - CCWP B
0
Normal
50
UNIT 3 - CEP B (CONDENSATE EXTRACTION PUMP)
0
Normal
51
UNIT 3 - DEMINERALIZED WATER PUMP A
0
Normal
52
UNIT 3 - HPU A
0
Normal
53
UNIT 3 - HPU B
0
Normal
Eskalasi & De-Eskalasi
Equipment
Transisi Level
Jenis
UNIT 3 - MAIN OIL TANK
Warning
Normal
De-eskalasi
BOILER FEED PUMP B UNIT 3
Warning
Normal
De-eskalasi
MOT BFP A
Warning
Normal
De-eskalasi
MOT BFP B
Warning
Normal
De-eskalasi
BOILER FEED PUMP C UNIT 3
Warning
Normal
De-eskalasi
UNIT 3 - IDF B (INDUCED DRAFT FAN)
Warning
Normal
De-eskalasi
UNIT 3 - MILL PULVERIZER A
Warning
Normal
De-eskalasi
UNIT 3 - MILL PULVERIZER B
Warning
Normal
De-eskalasi
UNIT 3 - COAL FEEDER A
Warning
Normal
De-eskalasi
UNIT 3 - MILL PULVERIZER D
Warning
Normal
De-eskalasi
TURBIN VELOCITY
Normal
Warning
Eskalasi
Kondisi Terakhir Peralatan
Thermal & Vibration
Oil Analysis
MCSA
DGA
PD
Peralatan
Semua
HP OIL PUMP
Sump Pump
DC OIL PUMP
BFP A
BFP B
BFP C
SWP A
SWP B
FWRO 1
FWRO 2
RO BOOSTER 1
HP PUMP SWRO A
HP PUMP SWRO B
JOCKEY PUMP A
JOCKEY PUMP B
BOOSTER PUMP A
BOOSTER PUMP B
EP - BC 1
EP - BC 2
EP - BC 3A
EP - BC 3B
EP - BC 4A
EP - BC 4B
EP - BC 5A
EP - BC 5B
EP - BC 6A
EP - BC 6B
PRIODICAL PUMP A
PRIODICAL PUMP B
UNIT 1 - MAIN OIL TANK
HYDRAULIC COUPLING PAF 1
BEARING PAF 1 B3
BEARING PAF 1 B4
HYDRAULIC COUPLING SAF 1
BEARING SAF 1 B3
BEARING SAF 1 B4
HYDRAULIC COUPLING IDF 1A
BEARING IDF 1A B3
BEARING IDF 1A B4
HYDRAULIC COUPLING IDF 1B
BEARING IDF 1B B3
BEARING IDF 1B B4
MOT BFP A
MOT BFP B
MOT BFP C
MOTOR CWP 1
MOTOR CWP 2
MOTOR CWP 3
MOTOR CWP 4
UNIT 2 - MAIN OIL TANK
HYDRAULIC COUPLING PAF 2
BEARING SAF 2 B3
BEARING PAF 2 B4
BEARING PAF 2 B3
BEARING SAF 2 B4
HYDRAULIC COUPLING IDF 2A
BEARING IDF 2A B3
BEARING IDF 2A B4
HYDRAULIC COUPLING IDF 2B
BEARING IDF 2B B3
BEARING IDF 2B B4
UNIT 3 - MAIN OIL TANK
CONTROL OIL TURBIN UNIT 3
BOILER FEED PUMP A UNIT 3
BOILER FEED PUMP B UNIT 3
BOILER FEED PUMP C UNIT 3
UNIT 3 - MILL PULVERIZER A
UNIT 3 - MILL PULVERIZER B
UNIT 3 - MILL PULVERIZER C
UNIT 3 - MILL PULVERIZER D
SERVICE WATER PUMP A
SERVICE WATER PUMP B
UNIT 3 - TERTIARY AIR FAN B
UNIT 3 - TERTIARY AIR FAN A
DEMINERALIZED WATER PUMP A
DEMINERALIZED WATER PUMP B
SWRO FEED PUMP A
SWRO FEED PUMP B
UNIT 3 - FORCED DRAFT FAN A
UNIT 3 - FORCED DRAFT FAN B
UNIT 3 - CRAVIMETRIC COAL FEEDER A
PRIMARY AIR FAN A
PRIMARY AIR FAN B
UNIT 3 - SCANNER COOLING AIR FAN A
UNIT 3 - SCANNER COOLING AIR FAN B
UNIT 3 - MAIN CIRCULATING WATER PUMP A
MAIN CIRCULATING WATER PUMP B
UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP A
UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP B
UNIT 3 - PRIMING PUMP
CONDENSER TUBE CLEANING
JACKING OIL PUMP A
JACKING OIL PUMP B
CONTR OIL COOLER CIRCULATION PUMP
OIL PURIFICATION PUMP
GLAND STEAM EXHAUSTER A
GLAND STEAM EXHAUSTER B
UNIT 3 - CRAVIMETRIC COAL FEEDER B
CLEAN OUT COAL FEEDER A
CLEAN OUT COAL FEEDER B
CLEAN OUT COAL FEEDER C
CLEAN OUT COAL FEEDER D
UNIT 3 - MILL OIL LUBRICATON PUMP A
UNIT 3 - MILL OIL LUBRICATON PUMP B
UNIT 3 - MILL OIL LUBRICATON PUMP C
UNIT 3 - MILL OIL LUBRICATON PUMP D
PYRITE SCRAPER CONVEYOR A
PYRITE SCRAPER CONVEYOR B
PYRITE SCRAPER CONVEYOR C
PYRITE SCRAPER CONVEYOR D
RECIPROCATING SOOTBLOWER A
RECIPROCATING SOOTBLOWER B
UNIT 3 - CRAVIMETRIC COAL FEEDER C
UNIT 3 - CRAVIMETRIC COAL FEEDER D
BACKWASH PUMP A
BACKWASH PUMP B
MMF BACKWASHING BLOWER A
MMF BACKWASHING BLOWER B
PORTABLE WATER FEED PUMP
BWRO FEED PUMP A
BWRO FEED PUMP B
MB FEED PUMP A
MB FEED PUMP B
PORTABLE WATER TRANSFER PUMP
BOILER INITIAL FILLING PUMP
BOP - FF JOCKEY PUMP FWP WTN
BOP - FF ELECTRIC FIRE PUMP FWP STN
FLOCCULANT PREPARATION AGITATOR A
FLOCCULANT PREPARATION AGITATOR B
UNIT 3 - BC 9B
UNIT 3 - BC 9A
UNIT 3 - BC 10A
UNIT 3 - BC 8A
UNIT 3 - BC 7A
FLASING WATER PUMP A
HYDRAULIC POWER UNIT
GT 1
UAT 1
GT 2
UAT 2
ESP 1.1
ESP 1.2
ESP 1.3
ESP 1.4
ESP 2.1
ESP 2.2
ESP 2.3
ESP 2.4
FIRE PUMP
GT 3
UAT 3
UNIT 3 - BC 8B
UNIT 3 - BC 7B
EP - JETTY CONVEYOR 02 A
EP - JETTY CONVEYOR 02 B
EP - JETTY CONVEYOR 01 B
UNIT 3 - FUEL FORWARDING PUMP A
UNIT 3 - FUEL FORWARDING PUMP B
EP - JETTY CONVEYOR 01 A
CLASIFIER B
GRINDING MILL -1
UNIT 3 - BC 10B
UNIT 3 - DOSER TRAP A
UNIT 3 - DOSER TRAP B
CLEARING COAL FEEDER NO. 1
CLEARING COAL FEEDER NO. 2
CLEARING COAL FEEDER NO. 3
CLEARING COAL FEEDER NO. 4
PRODUCT WATER PUMP B
PRODUCT WATER PUMP A
C
PARTIAL DISCHARGE
TRAFO GT UNIT 1
TRAFO UAT UNIT 1
TRAFO GT UNIT 2
TRAFO UAT UNIT 2
TRAFO GT UNIT 3
TRAFO UAT UNIT 3
CLASIFIER A
TURBIN DISPLACEMENT (O-P)
TURBIN VELOCITY
TURBIN DISPLACEMENT (RMS)
UNIT 3 - CRUSHER A
UNIT 3 - CRUSHER B
UNIT 2 - IDF A (INDUCED DRAFT FAN)
UNIT 2 - CEP A (CONDENSATE EXTRACTION PUMP)
UNIT 2 - CEP B (CONDENSATE EXTRACTION PUMP)
UNIT 2 - IDF B (INDUCED DRAFT FAN)
UNIT 2 - PAF (PRIMARY AIR FAN)
UNIT 1 - PAF (PRIMARY AIR FAN)
UNIT 2 - SAF (SECONDARY AIR FAN)
UNIT 2 - HP OIL PUMP
UNIT 3 - BFP A
UNIT 3 - BFP B
UNIT 3 - BFP C
UNIT 3 - PAF A (PRIMARY AIR FAN)
UNIT 3 - PAF B (PRIMARY AIR FAN)
UNIT 1 - VACUUM PUMP A
UNIT 1 - VACUUM PUMP B
UNIT 2 - VACUUM PUMP A
UNIT 3 - VACUUM PUMP A
UNIT 3 - VACUUM PUMP B
UNIT 2 - VACUUM PUMP B
A
B
UNIT 3 - MAIN CIRCULATING WATER PUMP B
UNIT 1 - SAF (SECONDARY AIR FAN)
UNIT 1 - IDF A (INDUCED DRAFT FAN)
UNIT 1 - IDF B (INDUCED DRAFT FAN)
UNIT 1 - CEP A (CONDENSATE EXTRACTION PUMP)
UNIT 1 - CEP B (CONDENSATE EXTRACTION PUMP)
UNIT 1 - HC IDF A
UNIT 1 - HC IDF B
UNIT 2 - HC IDF A
UNIT 2 - HC IDF B
UNIT 1 - HC SAF
UNIT 1 - HC PAF
UNIT 2 - HC PAF
UNIT 2 - HC SAF
UNIT 1 - HPFF A
UNIT 1 - HPFF B
UNIT 1 - HPFF C
UNIT 2 - HPFF A
UNIT 2 - HPFF B
UNIT 2 - HPFF C
UNIT 1 - GSF A (GLAND STEAM FAN)
UNIT 1 - GSF B (GLAND STEAM FAN)
UNIT 2 - GSF A (GLAND STEAM FAN)
UNIT 2 - GSF B (GLAND STEAM FAN)
UNIT 3 - GSF B (GLAND STEAM FAN)
UNIT 3 - GSF A (GLAND STEAM FAN)
UNIT 1 - CDAF (COAL DISTRIBUTION FAN)
UNIT 2 - CDAF (COAL DISTRIBUTION FAN)
UNIT 1 - COAL FEEDER A
UNIT 1 - COAL FEEDER B
UNIT 1 - COAL FEEDER C
UNIT 1 - COAL FEEDER D
UNIT 2 - COAL FEEDER A
UNIT 2 - COAL FEEDER B
UNIT 2 - COAL FEEDER C
UNIT 2 - COAL FEEDER D
UNIT 3 - COAL FEEDER A
UNIT 3 - COAL FEEDER B
UNIT 3 - COAL FEEDER C
UNIT 3 - COAL FEEDER D
UNIT 1 - OGE A (OIL GAS EXTRACTOR)
UNIT 1 - OGE B (OIL GAS EXTRACTOR)
UNIT 2 - OGE A (OIL GAS EXTRACTOR)
UNIT 2 - OGE B (OIL GAS EXTRACTOR)
UNIT 1 - HP OIL PUMP
UNIT 1 - JOP A
UNIT 1 - JOP B
UNIT 2 - JOP A
UNIT 2 - JOP B
UNIT 3 - JOP B
UNIT 3 - JOP A
UNIT 1 - AC OIL PUMP
UNIT 2 - AC OIL PUMP
UNIT 1 - DC OIL PUMP
UNIT 2 - DC OIL PUMP
UNIT 1 - TURNING GEAR
UNIT 2 - TURNING GEAR
UNIT 3 - TURNING GEAR
UNIT 3 - CCWP A
UNIT 3 - CCWP B
UNIT 3 - IDF A (INDUCED DRAFT FAN)
UNIT 3 - IDF B (INDUCED DRAFT FAN)
UNIT 3 - CEP A (CONDENSATE EXTRACTION PUMP)
UNIT 3 - CEP B (CONDENSATE EXTRACTION PUMP)
UNIT 3 - DEMINERALIZED WATER PUMP A
UNIT 3 - DEMINERALIZED WATER PUMP B
UNIT 3 - TURBIN DISPLACEMENT (O-P)
UNIT 3 - TURBIN DISPLACEMENT (RMS)
UNIT 3 - TURBIN VELOCITY
UNIT 3 - SERVICE WATER PUMP A
UNIT 3 - SERVICE WATER PUMP B
UNIT 3 - LUBE OIL PUMP B
UNIT 3 - LUBE OIL PUMP A
UNIT 3 - CLASIFIER A
UNIT 3 - CLASIFIER B
UNIT 3 - GRINDING MILL -1
UNIT 3 - CONTROL OIL SUPPLY PUMP A
UNIT 3 - CONTROL OIL SUPPLY PUMP B
UNIT 3 - CONTROL OIL COOLER FAN A
UNIT 3 - CONTROL OIL COOLER FAN B
BOP - BFP A
BOP - BFP B
BOP - BFP C
BOP - CWP A
BOP - CWP B
BOP - CWP C
BOP - CWP D
EP - CRUSHER A
EP - CRUSHER B
EP - SATELIN BASSIN A
EP - SATELIN BASSIN B
EP - STRAINER A2
EP - STRAINER A1
EP - STRAINER B1
EP - STRAINER B2
BOP - OCWP A
BOP - OCWP B
BOP - CCWP B
BOP - CCWP A
BOP - FEED PUMP A
BOP - FEED PUMP B
BOP - SWP A
BOP - SWP B
BOP - FWRO 1
BOP - RO BOSSTER 1
BOP - HP SWRO A
BOP - HP SWRO B
BOP - PX PUMP A
BOP - PX PUMP B
BOP - PRODUCT WATER PUMP A
BOP - PRODUCT WATER PUMP B
BOP - REGENERASION PUMP
BOP - FWRO 2
BOP - TBS 1 A
BOP - TBS 1 B
BOP - TBS 2 A
BOP - TBS 2 B
BOP - TBS 3 A
BOP - TBS 3 B
BOP - TBS 4 A
BOP - TBS 4 B
BOP - BFP A (LUBE OIL PUMP A)
BOP - BFP A (LUBE OIL PUMP B)
BOP - BFP B (LUBE OIL PUMP A)
BOP - BFP B (LUBE OIL PUMP B)
BOP - BFP C (LUBE OIL PUMP A)
BOP - BFP C (LUBE OIL PUMP B)
EP - FUEL OIL PUMP A
EP - FUEL OIL PUMP B
BOP - SERVICE WATER PUMP A
BOP - SERVICE WATER PUMP B
BOP - DEMINERALIZED WATER PUMP A
BOP - DEMINERALIZED WATER PUMP B
BFP D
MOT BFP D
UNIT 3 - HPU A
UNIT 3 - HPU B
Asset Wellness
Semua Asset Wellness
Good
Fine
Warning
Danger
Critical
Export
Excel
CSV
Peralatan
Unit
Tanggal
H2
CO2
CO
C2H4
C2H6
CH4
C2H2
TDCG
Rasio CO2/CO
Overall Status DGA
Water Content Kelman
Breakdown Voltage
Kondisi Trafo
Analisa Key Gas
Analisa Roger
Analisa Doernenburg
Analisa Duval
Analisa Japan ETRA
Problem
Possible Cause
Rekomendasi
TURBIN VELOCITY
Score 25.10 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
17
30%
5.1
Trend Condition
100
20%
20
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
25.1
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
1A
, nilai
3.87
, status
Fine
; skor severity
17
.
Trend Condition
: bernilai
100
karena status parameter
1A
naik dalam
0 hari
dari histori
26 Jan 2026
ke
26 Jan 2026
; masuk band
<= 14 hari
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
MOT BFP A
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
TAN
, nilai
1.47
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
TAN
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 2 - MAIN OIL TANK
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Cleanliness
, nilai
>28/28/22
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Cleanliness
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MILL PULVERIZER A
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Viscosity At 100deg
, nilai
1.9
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Viscosity At 100deg
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MILL PULVERIZER B
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Viscosity At 100deg
, nilai
20.2
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Viscosity At 100deg
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MILL PULVERIZER C
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Viscosity At 100deg
, nilai
19.3
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Viscosity At 100deg
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MILL PULVERIZER D
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Viscosity At 100deg
, nilai
19.1
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Viscosity At 100deg
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 9B
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Water
, nilai
545.5
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Water
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UAT 3
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
DGA
(
UNIT 3
), parameter
C2H6
, nilai
175
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena status parameter
C2H6
naik dalam
219 hari
dari histori
12 Jan 2026
ke
19 Aug 2026
; masuk band
> 60 hari
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
TURBIN DISPLACEMENT (RMS)
Score 22.50 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
75
30%
22.5
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
22.5
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
1A
, nilai
12.09
, status
Danger
; skor severity
75
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
1A
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MAIN OIL TANK
Score 20.80 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
50
30%
15
Trend Condition
29
20%
5.8
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
20.8
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Cleanliness
, nilai
19/18/14
, status
Warning
; skor severity
50
.
Trend Condition
: bernilai
29
karena status parameter
Cleanliness
naik dalam
56 hari
dari histori
09 Jul 2026
ke
03 Sep 2026
; masuk band
31-60 hari
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
BOILER FEED PUMP B UNIT 3
Score 15.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
50
30%
15
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
15
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Cleanliness
, nilai
21/19/14
, status
Warning
; skor severity
50
.
Trend Condition
: bernilai
0
karena status parameter
Cleanliness
naik dalam
154 hari
dari histori
02 Apr 2026
ke
03 Sep 2026
; masuk band
> 60 hari
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
BOILER FEED PUMP C UNIT 3
Score 15.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
50
30%
15
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
15
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Tribology
(
UNIT 3
), parameter
Viscosity At 40deg
, nilai
34.6
, status
Warning
; skor severity
50
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
Viscosity At 40deg
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - IDF A (INDUCED DRAFT FAN)
Score 11.25 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
75
15%
11.25
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
11.25
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
56.7
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
25
; polaritas negatif, skor ACR = 100 - rank =
75
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - IDF B (INDUCED DRAFT FAN)
Score 11.25 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
75
15%
11.25
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
11.25
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
55.7
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
25
; polaritas negatif, skor ACR = 100 - rank =
75
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - TERTIARY AIR FAN A
Score 2.70 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
9
30%
2.7
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
2.7
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
2H
, nilai
1.96
, status
Fine
; skor severity
9
.
Trend Condition
: bernilai
0
karena status parameter
2H
naik dalam
422 hari
dari histori
14 Jul 2025
ke
09 Sep 2026
; masuk band
> 60 hari
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
TURBIN DISPLACEMENT (O-P)
Score 2.10 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
7
30%
2.1
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
2.1
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
1A
, nilai
34.73
, status
Fine
; skor severity
7
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
1A
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
MAIN CIRCULATING WATER PUMP B
Score 2.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
40
5%
2
Engineering Assessment
0
30%
0
Total
2
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
49.6
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
1 kali
; skor damage history
40
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 9A
Score 1.80 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
6
30%
1.8
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
1.8
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
1H
, nilai
1.79
, status
Fine
; skor severity
6
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
1H
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - SERVICE WATER PUMP A
Score 0.90 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
3
30%
0.9
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0.9
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
2H
, nilai
1.78
, status
Fine
; skor severity
3
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
2H
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - FORCED DRAFT FAN A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
54.8
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - FORCED DRAFT FAN B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
55.6
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
PRIMARY AIR FAN A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
M. DE
, nilai
60.8
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
M. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
PRIMARY AIR FAN B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
61.3
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - SCANNER COOLING AIR FAN A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
60.1
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - SCANNER COOLING AIR FAN B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
M. DE
, nilai
43.5
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
M. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MAIN CIRCULATING WATER PUMP A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
54
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
63.1
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
62.5
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - PRIMING PUMP
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
34.1
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 10A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
51.7
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 8A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
51.5
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 8B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
49.6
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 7B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
4A
, nilai
2.96
, status
Fine
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada histori status lebih rendah
untuk parameter
4A
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - FUEL FORWARDING PUMP A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
M. DE
, nilai
58.4
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
M. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - FUEL FORWARDING PUMP B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
1V
, nilai
0.4
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
1V
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BC 10B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
44.7
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
TRAFO GT UNIT 3
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Trafo
(
UNIT 3
), parameter
Beban (MW)
, nilai
77.5
, status
-
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
Beban (MW)
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
TRAFO UAT UNIT 3
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Trafo
(
UNIT 3
), parameter
Beban (MW)
, nilai
77.5
, status
-
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
Beban (MW)
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - CRUSHER A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
47.9
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - BFP C
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
66.5
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - PAF A (PRIMARY AIR FAN)
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
M. DE
, nilai
60.8
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
M. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - PAF B (PRIMARY AIR FAN)
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
62
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - VACUUM PUMP A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
52.1
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - MAIN CIRCULATING WATER PUMP B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
52.5
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - COAL FEEDER A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. DE
, nilai
43.1
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - COAL FEEDER B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
37.4
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - COAL FEEDER D
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
38.8
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - CCWP B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
M. DE
, nilai
56.8
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
M. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - CEP B (CONDENSATE EXTRACTION PUMP)
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
M. DE
, nilai
54.4
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
M. DE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - DEMINERALIZED WATER PUMP A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
F/P. NDE
, nilai
54.4
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
F/P. NDE
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - HPU A
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
44.3
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.
UNIT 3 - HPU B
Score 0.00 - Normal
×
Parameter
Nilai
Bobot
Sub Total
Severity Level
0
30%
0
Trend Condition
0
20%
0
ACR Rank
0
15%
0
Riwayat Gangguan
0
5%
0
Engineering Assessment
0
30%
0
Total
0
Penjelasan Analisis Perhitungan
Severity Level
: diambil dari status tertinggi pada
Vibration & Thermal
(
UNIT 3
), parameter
WINDING
, nilai
43.6
, status
Good
; skor severity
0
.
Trend Condition
: bernilai
0
karena
Tidak ada kenaikan status yang perlu dipantau
untuk parameter
WINDING
.
ACR Rank
: rank
100
; polaritas negatif, skor ACR = 100 - rank =
0
.
Riwayat Gangguan
: tercatat
0 kali
; skor damage history
0
.
Engineering Assessment
: assessment
Tidak ada Concern
; skor assessment
0
.