UPDATE SR 31/08/2026

Unit Condition Distribution

Score Distribution

Normal 18 Alat (81.8%)
Warning 3 Alat (13.6%)
Danger 1 Alat (4.5%)
Critical 0 Alat (0%)

Priority Skoring Peralatan

# Equipment Name Score Status
1 UNIT 2 - IDF B (INDUCED DRAFT FAN) 52.05 Danger
2 UNIT 2 - VACUUM PUMP A 44.05 Warning
3 UNIT 2 - COAL FEEDER A 36.3 Warning
4 UNIT 2 - COAL FEEDER C 26.1 Warning
5 UNIT 1 - MAIN OIL TANK 22.5 Normal
6 BOILER FEED PUMP A UNIT 3 22.5 Normal
7 UNIT 2 - HPFF C 20.5 Normal
8 UNIT 2 - COAL FEEDER D 16.05 Normal
9 UNIT 2 - GSF A (GLAND STEAM FAN) 13.8 Normal
10 UNIT 2 - COAL FEEDER B 13.5 Normal
11 UNIT 2 - SAF (SECONDARY AIR FAN) 13.05 Normal
12 UNIT 2 - PAF (PRIMARY AIR FAN) 12.6 Normal
13 UNIT 2 - IDF A (INDUCED DRAFT FAN) 11.25 Normal
14 UNIT 2 - GSF B (GLAND STEAM FAN) 11.1 Normal
15 GT 2 9.3 Normal
16 UNIT 2 - HPFF B 8.6 Normal
17 UNIT 2 - HP OIL PUMP 4.8 Normal
18 UNIT 2 - CEP A (CONDENSATE EXTRACTION PUMP) 3.6 Normal
19 UNIT 2 - VACUUM PUMP B 1.5 Normal
20 UAT 2 0 Normal
21 TRAFO GT UNIT 2 0 Normal
22 TRAFO UAT UNIT 2 0 Normal

Eskalasi & De-Eskalasi

Equipment Transisi Level Jenis
UNIT 2 - COAL FEEDER C Normal Warning Eskalasi
UNIT 2 - COAL FEEDER A Normal Warning Eskalasi
UNIT 2 - VACUUM PUMP A Danger Warning De-eskalasi
BOILER FEED PUMP A UNIT 3 Warning Normal De-eskalasi
UNIT 2 - IDF B (INDUCED DRAFT FAN) Warning Danger Eskalasi
UNIT 2 - HP OIL PUMP Warning Normal De-eskalasi
UNIT 2 - MAIN OIL TANK Warning Normal De-eskalasi
Peralatan Unit Tanggal Merk Oli Spesifikasi Oli Cleanliness Specific Gravity Viscosity At 40deg Viscosity At 100deg TAN Water KET 1 KET 2