UPDATE SR 31/08/2026

Unit Condition Distribution

Score Distribution

Normal 145 Alat (91.8%)
Warning 11 Alat (7%)
Danger 2 Alat (1.3%)
Critical 0 Alat (0%)

Priority Skoring Peralatan

# Equipment Name Score Status
1 BOP - PX PUMP A 54.95 Danger
2 UNIT 2 - IDF B (INDUCED DRAFT FAN) 52.05 Danger
3 UNIT 1 - COAL FEEDER D 45.7 Warning
4 UNIT 2 - VACUUM PUMP A 44.05 Warning
5 BOP - CWP D 42.8 Warning
6 BOP - SWP A 42.5 Warning
7 UNIT 2 - COAL FEEDER A 36.3 Warning
8 MOT BFP C 30.7 Warning
9 BOP - FEED PUMP A 29.8 Warning
10 BOP - BFP A 29.2 Warning
11 BOP - CWP A 27 Warning
12 BOP - OCWP B 26.3 Warning
13 UNIT 2 - COAL FEEDER C 26.1 Warning
14 UNIT 1 - MAIN OIL TANK 22.5 Normal
15 MOT BFP A 22.5 Normal
16 UNIT 2 - MAIN OIL TANK 22.5 Normal
17 BOILER FEED PUMP A UNIT 3 22.5 Normal
18 UNIT 3 - MILL PULVERIZER A 22.5 Normal
19 UNIT 3 - MILL PULVERIZER B 22.5 Normal
20 UNIT 3 - MILL PULVERIZER C 22.5 Normal
21 UNIT 3 - MILL PULVERIZER D 22.5 Normal
22 UNIT 3 - BC 9B 22.5 Normal
23 GT 3 22.5 Normal
24 UAT 3 22.5 Normal
25 BOP - BFP C (LUBE OIL PUMP A) 22.1 Normal
26 BOP - CWP B 21.9 Normal
27 UNIT 1 - VACUUM PUMP B 21.25 Normal
28 EP - CRUSHER A 20.9 Normal
29 UNIT 3 - MAIN OIL TANK 20.8 Normal
30 UNIT 2 - HPFF C 20.5 Normal
31 UNIT 1 - SAF (SECONDARY AIR FAN) 19.2 Normal
32 UNIT 1 - PAF (PRIMARY AIR FAN) 19 Normal
33 UNIT 1 - COAL FEEDER C 18 Normal
34 UNIT 1 - COAL FEEDER B 16.6 Normal
35 UNIT 2 - COAL FEEDER D 16.05 Normal
36 BOILER FEED PUMP B UNIT 3 15 Normal
37 BOILER FEED PUMP C UNIT 3 15 Normal
38 BOP - CWP C 14.7 Normal
39 UNIT 2 - GSF A (GLAND STEAM FAN) 13.8 Normal
40 UNIT 2 - COAL FEEDER B 13.5 Normal
41 UNIT 1 - VACUUM PUMP A 13.35 Normal
42 UNIT 2 - SAF (SECONDARY AIR FAN) 13.05 Normal
43 UNIT 2 - PAF (PRIMARY AIR FAN) 12.6 Normal
44 UNIT 3 - BC 7A 12 Normal
45 UNIT 1 - COAL FEEDER A 12 Normal
46 UNIT 1 - GSF A (GLAND STEAM FAN) 11.8 Normal
47 TRAFO GT UNIT 1 11.25 Normal
48 TRAFO UAT UNIT 1 11.25 Normal
49 UNIT 2 - IDF A (INDUCED DRAFT FAN) 11.25 Normal
50 UNIT 1 - IDF A (INDUCED DRAFT FAN) 11.25 Normal
51 UNIT 1 - IDF B (INDUCED DRAFT FAN) 11.25 Normal
52 UNIT 3 - IDF A (INDUCED DRAFT FAN) 11.25 Normal
53 UNIT 3 - IDF B (INDUCED DRAFT FAN) 11.25 Normal
54 BOP - CCWP B 11.2 Normal
55 UNIT 2 - GSF B (GLAND STEAM FAN) 11.1 Normal
56 BOP - DEMINERALIZED WATER PUMP A 10.2 Normal
57 GT 2 9.3 Normal
58 UNIT 2 - HPFF B 8.6 Normal
59 BOP - BFP A (LUBE OIL PUMP A) 8.5 Normal
60 UNIT 1 - CEP B (CONDENSATE EXTRACTION PUMP) 6.8 Normal
61 BOP - DEMINERALIZED WATER PUMP B 5.7 Normal
62 UNIT 2 - HP OIL PUMP 4.8 Normal
63 UNIT 1 - HPFF B 4.8 Normal
64 BOP - BFP B 4.5 Normal
65 BOP - BFP C (LUBE OIL PUMP B) 4.5 Normal
66 BOP - BFP C 3.8 Normal
67 UNIT 2 - CEP A (CONDENSATE EXTRACTION PUMP) 3.6 Normal
68 EP - CRUSHER B 3 Normal
69 UNIT 3 - TERTIARY AIR FAN A 2.7 Normal
70 BOP - PX PUMP B 2.1 Normal
71 UNIT 3 - BC 9A 1.8 Normal
72 BOP - CCWP A 1.8 Normal
73 BOP - HP SWRO B 1.8 Normal
74 UNIT 2 - VACUUM PUMP B 1.5 Normal
75 UNIT 3 - TERTIARY AIR FAN B 1.2 Normal
76 UNIT 3 - SERVICE WATER PUMP A 0.9 Normal
77 EP - BC 3A 0 Normal
78 EP - BC 3B 0 Normal
79 EP - BC 4A 0 Normal
80 EP - BC 4B 0 Normal
81 EP - BC 5A 0 Normal
82 EP - BC 5B 0 Normal
83 EP - BC 6A 0 Normal
84 EP - BC 6B 0 Normal
85 MOT BFP B 0 Normal
86 UNIT 3 - FORCED DRAFT FAN A 0 Normal
87 UNIT 3 - FORCED DRAFT FAN B 0 Normal
88 UNIT 3 - SCANNER COOLING AIR FAN A 0 Normal
89 UNIT 3 - SCANNER COOLING AIR FAN B 0 Normal
90 UNIT 3 - MAIN CIRCULATING WATER PUMP A 0 Normal
91 UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP A 0 Normal
92 UNIT 3 - (ACWP) AUXILIARY CIRCULATING WATER PUMP B 0 Normal
93 UNIT 3 - PRIMING PUMP 0 Normal
94 UNIT 3 - BC 10A 0 Normal
95 UNIT 3 - BC 8A 0 Normal
96 GT 1 0 Normal
97 UAT 1 0 Normal
98 UAT 2 0 Normal
99 UNIT 3 - BC 8B 0 Normal
100 UNIT 3 - BC 7B 0 Normal
101 EP - JETTY CONVEYOR 02 A 0 Normal
102 EP - JETTY CONVEYOR 02 B 0 Normal
103 EP - JETTY CONVEYOR 01 B 0 Normal
104 UNIT 3 - FUEL FORWARDING PUMP A 0 Normal
105 UNIT 3 - FUEL FORWARDING PUMP B 0 Normal
106 EP - JETTY CONVEYOR 01 A 0 Normal
107 UNIT 3 - BC 10B 0 Normal
108 PRODUCT WATER PUMP B 0 Normal
109 PRODUCT WATER PUMP A 0 Normal
110 PARTIAL DISCHARGE 0 Normal
111 TRAFO GT UNIT 2 0 Normal
112 TRAFO UAT UNIT 2 0 Normal
113 TRAFO GT UNIT 3 0 Normal
114 TRAFO UAT UNIT 3 0 Normal
115 UNIT 3 - CRUSHER A 0 Normal
116 UNIT 3 - CRUSHER B 0 Normal
117 UNIT 2 - CEP B (CONDENSATE EXTRACTION PUMP) 0 Normal
118 UNIT 3 - BFP A 0 Normal
119 UNIT 3 - BFP B 0 Normal
120 UNIT 3 - BFP C 0 Normal
121 UNIT 3 - PAF A (PRIMARY AIR FAN) 0 Normal
122 UNIT 3 - PAF B (PRIMARY AIR FAN) 0 Normal
123 UNIT 3 - VACUUM PUMP A 0 Normal
124 UNIT 3 - VACUUM PUMP B 0 Normal
125 UNIT 3 - MAIN CIRCULATING WATER PUMP B 0 Normal
126 UNIT 1 - CEP A (CONDENSATE EXTRACTION PUMP) 0 Normal
127 UNIT 1 - HPFF A 0 Normal
128 UNIT 1 - HPFF C 0 Normal
129 UNIT 2 - HPFF A 0 Normal
130 UNIT 1 - GSF B (GLAND STEAM FAN) 0 Normal
131 UNIT 3 - GSF B (GLAND STEAM FAN) 0 Normal
132 UNIT 3 - GSF A (GLAND STEAM FAN) 0 Normal
133 UNIT 3 - COAL FEEDER A 0 Normal
134 UNIT 3 - COAL FEEDER B 0 Normal
135 UNIT 3 - COAL FEEDER C 0 Normal
136 UNIT 3 - COAL FEEDER D 0 Normal
137 UNIT 1 - HP OIL PUMP 0 Normal
138 UNIT 3 - CCWP A 0 Normal
139 UNIT 3 - CCWP B 0 Normal
140 UNIT 3 - CEP A (CONDENSATE EXTRACTION PUMP) 0 Normal
141 UNIT 3 - CEP B (CONDENSATE EXTRACTION PUMP) 0 Normal
142 UNIT 3 - DEMINERALIZED WATER PUMP A 0 Normal
143 UNIT 3 - DEMINERALIZED WATER PUMP B 0 Normal
144 UNIT 3 - TURBIN DISPLACEMENT (O-P) 0 Normal
145 UNIT 3 - TURBIN DISPLACEMENT (RMS) 0 Normal
146 UNIT 3 - TURBIN VELOCITY 0 Normal
147 UNIT 3 - SERVICE WATER PUMP B 0 Normal
148 BOP - OCWP A 0 Normal
149 BOP - FEED PUMP B 0 Normal
150 BOP - SWP B 0 Normal
151 BOP - FWRO 1 0 Normal
152 BOP - HP SWRO A 0 Normal
153 BOP - FWRO 2 0 Normal
154 BOP - BFP A (LUBE OIL PUMP B) 0 Normal
155 BOP - BFP B (LUBE OIL PUMP A) 0 Normal
156 BOP - BFP B (LUBE OIL PUMP B) 0 Normal
157 UNIT 3 - HPU A 0 Normal
158 UNIT 3 - HPU B 0 Normal

Eskalasi & De-Eskalasi

Equipment Transisi Level Jenis
BOP - BFP A Normal Warning Eskalasi
UNIT 2 - COAL FEEDER C Normal Warning Eskalasi
UNIT 2 - COAL FEEDER A Normal Warning Eskalasi
BOP - CWP A Normal Warning Eskalasi
BOP - SWP A Normal Warning Eskalasi
BOP - CWP D Normal Warning Eskalasi
UNIT 3 - MAIN OIL TANK Warning Normal De-eskalasi
UNIT 1 - MAIN OIL TANK Warning Normal De-eskalasi
UNIT 2 - VACUUM PUMP A Danger Warning De-eskalasi
BOILER FEED PUMP B UNIT 3 Warning Normal De-eskalasi
MOT BFP A Warning Normal De-eskalasi
BOILER FEED PUMP A UNIT 3 Warning Normal De-eskalasi
MOT BFP B Warning Normal De-eskalasi
BOILER FEED PUMP C UNIT 3 Warning Normal De-eskalasi
BOP - OCWP B Normal Warning Eskalasi
UNIT 1 - COAL FEEDER A Warning Normal De-eskalasi
UNIT 3 - IDF B (INDUCED DRAFT FAN) Warning Normal De-eskalasi
UNIT 3 - MILL PULVERIZER A Warning Normal De-eskalasi
UNIT 3 - MILL PULVERIZER B Warning Normal De-eskalasi
UNIT 2 - IDF B (INDUCED DRAFT FAN) Warning Danger Eskalasi
BOP - PX PUMP A Normal Danger Eskalasi
UNIT 3 - COAL FEEDER A Warning Normal De-eskalasi
UNIT 1 - COAL FEEDER D Normal Warning Eskalasi
BOP - FEED PUMP A Normal Warning Eskalasi
UNIT 2 - HP OIL PUMP Warning Normal De-eskalasi
UNIT 3 - MILL PULVERIZER D Warning Normal De-eskalasi
UNIT 2 - MAIN OIL TANK Warning Normal De-eskalasi
Silakan Pilih Unit Terlebih Dahulu

Tabel Kondisi Terakhir Peralatan memerlukan spesifikasi unit. Mohon pilih salah satu unit (UNIT 1, UNIT 2, UNIT 3, DLL) pada tombol di pojok kanan atas halaman untuk menampilkan data.